PowerStationFacts
Jackery Explorer 300

Jackery Explorer 300

293 WhCapacity300 WAC output500 WSurge7.1 lb (3.2 kg)WeightNo UPS functionUPS switchover800 cycles to 80%Cycle life

The Explorer 300 holds 293 Wh behind 300 W of continuous AC output. It scores 3.4 out of 10 against the rest of this catalogue, ranking 8 of 8 in its size class. On the numbers, it carries more watt hours per kilo than most. The figure to watch is the other way: its rated cycle life is short next to current lithium iron phosphate packs.

PowerStationFacts takes part in the Amazon Services LLC Associates Program. When you buy through a link on this page we may earn a commission, and the price you pay does not change.

Stacked power stations and a solar panel at a gravel campsite
Stacked power stations and a solar panel at a gravel campsite
3.4/10

Our score

Ranked 8 of 8 among units under 500 Wh

Capacity3.3
AC output2.0
Recharge speed2.0
Cycle life2.0
Watt hours per kilo8.1
Backup switchoverNot published

Scored on 90% of the weighting: the maker does not publish every figure.

Scores are calculated from published specifications, not opinion. How the score is built

The full specification

Every figure below is read from the maker's own specification page. Where a value is missing, it is missing because Jackery does not publish it, not because it was too much trouble to find.

Jackery Explorer 300
Capacity293 Wh
AC output300 W
Surge500 W
Cell chemistryLithium-ion
Cycle life800 cycles to 80%
Wall recharge4.5 hours
Max solar inputNot published
UPS switchoverNo UPS function
Weight7.1 lb (3.2 kg)
Extra batteriesNot expandable

Where it is strong, and where it is not

  • Watt hours per kilo. On this axis it carries more watt hours per kilo than most.

What should give you pause

  • Cycle life. Here its rated cycle life is short next to current lithium iron phosphate packs.
  • AC output. Here continuous output is limited, so heating appliances are out of reach.
  • Recharge speed. Here it refills slowly, which matters between two outages.
  • Expansion. This unit takes no second battery. The capacity it has on the day you buy it is the capacity it keeps.
  • Backup. No switchover time is published, so do not assume it will carry a desktop or a CPAP machine through a cut without testing it yourself.

What it will actually run

These estimates use the same arithmetic as the run time calculator: usable watt hours after an assumed 85% inverter efficiency, divided by the appliance's average draw rather than its peak. The fridge figure assumes the compressor runs about a third of the time, which is what makes it plausible.

ApplianceTypical drawEstimated run time
Fridge120 W5 h 56 min
CPAP machine45 W5 h 32 min
Router and modem15 W16 h 36 min
Television90 W2 h 46 min
Microwave1200 W0 h 12 min

Read the rating plate on your own appliance before trusting any of these. The wattages above are common starting points, not measurements of your kit.

The closest alternatives

The units nearest this one in capacity, with their own scores. Capacity is the honest axis to shortlist on: two units of the same size are genuinely substitutable, and everything else is a trade.

Every power station covered on this site, with capacity, continuous AC output and weight
#BrandModelScoreCapacityAC outputWeightActions
1Anker SOLIX C300 DC5.9/10288 WhNot published6.2 lb (2.8 kg)Check price
2Anker SOLIX C3004.7/10288 Wh300 W9.1 lb (4.1 kg)Check price
3EcoFlow RIVER 3 Plus4.4/10286 Wh600 W10.4 lb (4.7 kg)Check price

Common questions

How long will the Explorer 300 run a fridge?

See the table above. The figure assumes an average domestic fridge and a compressor running about a third of the time. A warm room, a full shelf of fresh shopping or a door that keeps opening all push the real duty cycle up and the run time down.

Can I add capacity later?

No. The maker's specification table lists this unit as not expandable. If you might need more capacity, buy larger now or choose a model designed to take a second battery.

What does the cycle rating promise?

That after 800 cycles to 80%, the pack still holds the stated share of its original capacity. It is a degradation threshold, not a failure point. Always note the endpoint when comparing against another maker: they do not all quote the same one.